Game controller Hall joysticks/magnetic-axis mechanical keyboards, PV inverter/energy-storage BMS current sensing, automotive electronic throttle pedals (TPS), industrial robot joint angle, smart liquid/fluid level detection, EV OBC/DC-DC current sampling, AC charging pile residual current (RCD), servo drive phase current, inverter air conditioner/induction cooker over-current protection

ModelTypeTemperatureVoltagePackage
OH49EOH49E-SLinear Hall IC-20~100℃3.0-6.5VSOT89 / SOT23 / TO-92S
OH495AOH496BLinear Hall IC-20~125℃4.5-10.5VSOT89 / TO-92S
OH549ELinear Hall IC-20~100℃2.3~10VSOT89
OH12A InSb Hall effect ElementHall Element-40 to 120 ℃Vin=1V,B=500G (Constant VoltageSOT143 / 3000 pcs/reel
OH12AF-L InSb Hall effect ElementHall Element-40 to 120 ℃Vin=1V,B=500G (Constant Voltage)3000 pcs/reel
OH82A Miniature Insb Hall effect ElementHall Element-40 to 120 ℃Vin=1V, B=500G (Constant Voltage)4000 pcs/reel
OH41OH41ABipolar & Latch Hall IC-40~150℃4.5~ 24VTO-92S
OH920Bipolar & Latch Hall IC-40~150℃3.5~ 20VSOT23

Application Focus

Aerospace Position & Speed SensingHigh-reliability position, speed and rotation sensing for aerospace mechanisms.

Aerospace mechanism position and speed sensing commonly uses a gear-tooth target wheel with a back-bias sensor, or a magnet on the shaft end face with a linear Hall sensor for angle. Actuator, cylinder and drive-shaft position feedback require stable signals and good repeatability, while speed and phase require no missed pulses across the full speed range. Hall sensing is contactless, with no sliding contacts or exposed actuators, making it suitable for locations with long maintenance intervals.

Gear / tooth ring passes → one pulse per tooth
Applicable types
Gear-tooth sensor, Linear analog
Operating temperature
-55~150°C
Supply voltage
5 V logic
Output
Analog voltage, Digital switch
AEC-Q100
Required
Operating environment
Aerospace high-vibration, wide-temperature, high-reliability environment for gear/shaft position and speed detection.
Confirm before selection
Gear module/tooth form and mounting air gap; analog position or speed pulse output; temperature range and screening level (aerospace screening required); supply voltage and output interface.

Key points

  • Separate mechanical from sensor error. Target-wheel tooth form, face runout, bearing play and bracket stiffness all affect the signal; the sensor itself is only one part of the measurement chain.
  • Air gap across the full speed range. Set the air gap from maximum speed and maximum vibration, ensuring sufficient amplitude without risking contact.
  • Independent redundant channels. For redundant signals, keep supply, ground and connectors as independent as possible so a single-point failure cannot affect multiple channels.

FAQ

Pulses are lost at high speed — how should I troubleshoot?
Check air gap, target-wheel tooth form and filter settings, and confirm sufficient amplitude at maximum speed.
Position feedback repeatability is poor — what causes it?
Check target-wheel runout, bearing play and bracket stiffness, then decide whether recalibration is needed.
Signal is abnormal at low temperature — what should I do?
Check the sensor low-temperature range and harness material, and connector contact at low temperature.
Redundant channels disagree — what should I do?
Check supply, ground and mounting angle of each channel, and confirm the channels do not share a common failure path.
Phase error after maintenance — how should I troubleshoot?
Verify target-wheel mounting angle and reference-tooth position, and reconfirm phase relationships per the maintenance procedure.
Automotive Steering AngleSteering-wheel angle measurement for ESP and vehicle stability control.

Steering-wheel angle detection supports stability control, lane keeping and steering assist. A common design mounts a magnet and linear Hall sensor on the steering column, reading single-turn angle; because the wheel can turn more than one revolution, a gear set or algorithm accumulates turns to give a signed absolute angle. Dual Hall outputs can also provide redundancy and direction.

Angle feedback: radial magnet + Hall
Applicable types
Linear analog, Hall element
Operating temperature
-40~150°C
Supply voltage
5 V logic, 12 V vehicle system
Output
Analog voltage, PWM
AEC-Q100
Required
Operating environment
Engine bay or near the steering column with wide temperature, vibration, oil mist and electromagnetic interference; 12 V vehicle supply.
Confirm before selection
Angle range and accuracy; analog voltage or PWM/SPI output; mounting air gap and magnet scheme (type, field strength); AEC-Q100 and specific temperature grade.

Key points

  • Coaxiality and air gap. The steering column has bearing play and axial movement; the bracket must be stiff so the air gap does not change during rotation.
  • Zero calibration. The steering centre must correspond to zero degrees; recalibrate after replacing the column or performing wheel alignment.
  • Redundancy and routing. Keep signal wires away from motors and high-current circuits; assess the failure direction of angle signals used in control.

FAQ

The wheel is centred but the angle is not zero — what should I check first?
Check zero calibration and mounting position, and whether the system was recalibrated after replacing the column or sensor.
Left and right outputs are asymmetric — what should I do?
Check magnet-to-Hall coaxiality, steering-column play and calibration parameters.
Angle jumps after passing one revolution — what causes it?
Check the multi-turn accumulation logic, gear-set backlash or algorithm boundary conditions.
The angle signal is intermittently abnormal while driving — how should I troubleshoot?
Check harness wear, connector vibration and wiring near the airbag clock spring.
What must be done after replacing the steering column?
Verify magnet position, zero point and steering ratio, and follow the vehicle calibration procedure.
Automotive Suspension HeightBody-to-ground height detection for air suspension adjustment.

Air-suspension height detection usually connects the body and suspension arm with a linkage; as the linkage rotates or moves it drives a magnet, and a Hall sensor fixed to the chassis or body bracket reads the displacement. The controller adjusts air-spring pressure from left/right and front/rear height signals to maintain body attitude. The sensor measures relative displacement at the linkage and converts it to body height through linkage geometry.

Linear Hall: field varies with displacement → analog voltage
Applicable types
Linear analog
Operating temperature
-40~150°C
Supply voltage
5 V from regulated 12 V vehicle supply
Output
Analog voltage
AEC-Q100
Required
Operating environment
Underbody/suspension area with wide temperature, vibration, mud, water and salt spray; dust and water protection required; 12 V vehicle supply via a regulator.
Confirm before selection
Measurement travel/angle range; target magnet type, field strength and air gap; analog voltage or PWM and the ECU's expected voltage range; mounting space and package; whether AEC-Q100 is required.

Key points

  • Linkage geometry and travel. Linkage length, pivot position and magnet travel must match the suspension movement range.
  • Full-travel air gap and stiffness. The air gap must stay stable as the suspension moves, and the bracket must not be deformed by mud or stones.
  • Protection and calibration. The underbody sees mud, water, stones and salt spray; check unladen, laden and lifted states point by point.

FAQ

Displayed height does not match reality — what should I check first?
Check linkage geometry, magnet position and calibration parameters, and confirm the suspension is in the standard state.
Left and right heights differ — what should I do?
Check linkage mounting angle, bracket deformation and sensor zero, then recalibrate per the vehicle procedure.
Height adjusts frequently over bumps — what causes it?
Check signal chatter, linkage ball-joint wear and the control strategy's filter settings.
Abnormal after mud or water — how should I troubleshoot?
Check sensor sealing, connector water ingress and whether mud is jamming the linkage.
What must be done after replacing suspension parts?
Verify linkage length, mounting position and height-sensor zero, and follow the service manual.
Electronic CompassGeomagnetic direction measurement for compasses and electronic compass modules.

An electronic compass measures the horizontal component of the Earth's field: two-axis magnetic sensors read the X and Y fields and the controller uses arctangent to calculate the device heading. A three-axis design can also measure the vertical component and use an accelerometer for tilt compensation, giving a usable heading even when the device is not level. Linear Hall sensors can provide analog field measurement, but device selection must consider whether sensitivity and noise suit the geomagnetic field level.

Electronic compass: two axis components give geomagnetic heading
Applicable types
Linear analog, Hall element
Operating temperature
-20~85°C
Supply voltage
3.3 V
Output
Analog voltage
AEC-Q100
Not required
Operating environment
Consumer electronics indoors at ambient temperature, battery-powered; low power and low noise needed; the weak geomagnetic field (about 0.5 Gs) requires high sensitivity and low hysteresis; no water/dust protection.
Confirm before selection
Field range (geomagnetic about ±0.5 Gs or 0~20 Gs with bias); sensitivity/resolution (can a 1° direction change be resolved); 3.3 V or 5 V and battery power constraints; analog voltage or integrated digital angle/heading signal.

Key points

  • Keep away from internal magnetic sources. Speakers, vibration motors, autofocus coils and batteries introduce fixed or state-dependent fields; keep the sensor at a distance.
  • Align coordinates with the housing datum. Sensor axes must align with the housing datum direction; mounting rotation must be calibrated in software.
  • Hard- and soft-iron calibration. Errors from ferrous parts can only be removed by calibration, and drift can still follow temperature, battery position and housing magnetization.

FAQ

The heading has a fixed offset — what should I do?
Check sensor mounting direction against the housing datum, and redo hard- and soft-iron calibration.
Heading gets much worse when the device tilts — what should I do?
Check whether tilt compensation is implemented; a two-axis design has larger error when not level.
The needle jumps near a speaker or motor — what should I do?
This is local magnetic interference; adjust the layout or avoid the source during use.
It is correct after calibration but drifts later — what should I do?
Check housing magnetization, battery position changes and temperature effects, and recalibrate if needed.
Units differ significantly — what should I do?
Check batch differences in speakers and magnets, and calibrate each unit on the production line.
Navigation System PositionAngle and position detection in vehicle and consumer navigation devices.

Position detection in navigation devices usually concerns the angle of a knob, flip cover, gimbal or direction mechanism. A radially magnetized magnet is fixed to the shaft and a Hall chip is soldered to the PCB below it, coaxially. As the magnet rotates the field direction changes continuously: a linear Hall sensor outputs an analog voltage, while a bipolar latch outputs two phase-shifted pulses from which the controller calculates angle and rotation direction.

Angle feedback: radial magnet + Hall
Applicable types
Linear analog, Omnipolar switch
Operating temperature
-40~105°C
Supply voltage
5 V
Output
Analog voltage, Digital switch
AEC-Q100
Not required
Operating environment
Inside vehicle or consumer navigation equipment with vehicle vibration and temperature variation; not engine-bay; vehicle power supply.
Confirm before selection
Angle/displacement or end-position switch; required accuracy and linearity; mounting air gap and magnet specification; temperature range and supply voltage.

Key points

  • Concentricity and air gap. Magnet eccentricity makes the output waveform asymmetric, and too large an air gap weakens the signal and raises the noise share.
  • Evaluate stray fields near the shaft. Assess motors, speakers and wireless-charging coils first; increase distance or change magnet orientation if needed.
  • Supply decoupling and analog routing. Vehicle or portable supplies fluctuate; add decoupling at the Hall supply and keep the analog output away from power wiring.

FAQ

The angle reading jumps — what should I do?
This is usually magnet eccentricity, air-gap change or supply noise; check coaxiality first, then supply decoupling and output routing.
Rotation direction is misjudged — what should I do?
Check the relative position of the two Hall sensors and the controller decoding order; phase depends on mounting angle.
Zero drifts with temperature — what should I do?
Magnet flux and Hall zero change with temperature; recalibrate over the product operating temperature range.
Abnormal near a motor or speaker — what should I do?
Stray fields add to the detection field; change the mounting position or add magnetic shielding and retest.
Accuracy drops after mechanical loosening — what should I do?
Shaft bearing wear or poor PCB fixing changes the air gap; rule out mechanical causes before checking the circuit.
Banknote AuthenticationMagnetic feature detection in banknote validators for authenticity and denomination recognition.

Magnetic detection in a banknote validator targets the magnetic ink and security thread on the note: the note passes the magnetic sensor at a stable speed, the magnetic region produces a peak in the sensor output, and the position and amplitude of the signal are compared with a genuine-note template as one basis for authenticity and denomination. The sensor can be a single Hall sensor, a Hall array or a magnetic head, depending on the transport structure and the features to be recognized.

Banknote magnetic check: magnetic ink passes the sensor; output follows the pattern
Applicable types
Linear analog, Hall element
Operating temperature
-10~60°C
Supply voltage
5 V
Output
Analog voltage
AEC-Q100
Not required
Operating environment
Inside a validator at ambient temperature with banknotes passing at high speed; weak fields from magnetic ink and security threads require low noise and high sensitivity; no water/dust protection.
Confirm before selection
Magnetic ink or security thread, and approximate field strength; required sensitivity/resolution and analog or switch output; sensor-to-note detection distance (air gap); supply voltage and output interface.

Key points

  • Stable note transport. Feed rollers, pinch wheels and guides must not let the note arch or shift; a stable note-to-sensor distance makes waveform positions comparable.
  • Match array spacing to feature size. Array pitch must match the feature size to be recognized, and stable transport speed prevents the waveform from being stretched or compressed in time.
  • Surface wear and standard-sample checks. The sensor surface must be wear-resistant and easy to clean; magnetic-head wear or Hall position change is found by periodic standard-sample verification.

FAQ

Genuine notes are frequently rejected — what should I do?
Check transport speed, note-to-sensor spacing, and whether the sensor surface is worn or contaminated.
Recognition rate is low for a particular denomination — what should I do?
Check the template library and sensor-array position, and confirm the denomination's magnetic features fall in the effective detection zone.
Waveform position drifts — what should I do?
Check whether the feed roller slips, the guide shifts the note, and the encoder/speed signal is stable.
Old and new notes behave very differently — what should I do?
This depends on note condition; adjust the criteria or add other features for a combined decision.
Sensitivity drops after long use — what should I do?
Clean the sensor surface, check magnetic-head wear or Hall position change, and verify periodically with standard samples.
AC Variable-Frequency DriveHigh-frequency and pulse current sensing in AC variable-frequency drives.

Current sensing in a variable-frequency drive usually passes a busbar or cable through a magnetic core and places a Hall element in the core gap. The primary current produces flux proportional to current, and the Hall output is conditioned, isolated and digitized before entering the DSP for closed-loop control, over-current protection and fault detection. Compared with a shunt resistor, a Hall design has no insertion loss, does not bring power-stage heat into the measurement circuit, and preserves electrical isolation.

Hall current sensing: primary current → flux → isolated output
Applicable types
Linear Hall, Hall element
Operating temperature
-40~105°C
Supply voltage
5 V
Output
Analog voltage
AEC-Q100
Not required
Operating environment
Inside industrial VFD cabinets with high-frequency pulse currents, electromagnetic interference, vibration and elevated temperature.
Confirm before selection
AC or pulse current, range and frequency; isolated or non-isolated measurement; supply and output form (voltage/current/differential); ambient temperature and mounting method (PCB or through-hole).

Key points

  • Conductor centering and core fixing. The primary conductor must pass through the core centre without eccentricity or tilt, and the core fixing must resist vibration and assembly stress.
  • Small-signal routing and isolation. The Hall output is a small signal; keep it short and away from IGBT drives and busbars. Isolation creepage and clearance must match the cabinet voltage class.
  • PWM synchronization and saturation protection. Synchronize sampling with PWM to avoid switching spikes, and use a comparator or threshold for core saturation.

FAQ

Current spikes and false over-current at switching — what should I check first?
This is usually sampling on a switching edge or dv/dt pickup on the signal line; check PWM/ADC synchronization and shorten the signal wire.
Zero shifts at low current — what could cause it?
Hall and amplifier zero drift with temperature, or the core has remanence or a nearby constant external field.
Output saturates at high current — what should I do?
Check core cross-section, air gap and Hall range; short-circuit protection should also use a separate comparator threshold.
Drift or false protection at high temperature — what should I do?
Cabinet temperature is high; check whether the sensor is near heat sources, adjust airflow or use a wide-temperature device.
Isolation failure or common-mode interference — how should I troubleshoot?
Check isolation devices, creepage and grounding, and confirm signal ground is not accidentally connected to power ground.
Anemometer Wind SpeedRotation detection of wind cups or impellers for wind-speed measurement.

An anemometer turns the rotation of wind cups or an impeller into electrical pulses: a magnet is fixed to the cup assembly or impeller and a Hall switch is fixed in the bracket, so each revolution passes the sensing face a fixed number of times and produces a fixed number of pulses. The controller converts pulse frequency and pulses per revolution into speed, then applies the cup constant or impeller calibration curve to obtain wind speed. Compared with a reed switch, a Hall sensor has no glass tube or contacts, resists vibration and is easier to seal.

Cups / impeller + magnet: rotation becomes wind-speed pulses
Applicable types
Unipolar switch, Gear-tooth sensor
Operating temperature
-40~85°C
Supply voltage
Battery or low-voltage supply
Output
Digital switch
AEC-Q100
Not required
Operating environment
Industrial site with wind cups/impeller rotation; vibration, dust and moisture resistance required; possibly battery or low-voltage supply.
Confirm before selection
Magnet pole and field strength on the impeller; sensor-to-magnet mounting air gap; output frequency at maximum speed; supply voltage and output form (open-drain/pull-up/square wave).

Key points

  • Dynamic balance and bearing drag. The rotating assembly must be well balanced with low, consistent bearing drag; cup deformation or extra drag lowers readings at low wind speed.
  • Even air gap and outdoor sealing. The air gap must be even around the full turn without rubbing; the outdoor cavity must be sealed, with the wire exit facing down and a drip loop.
  • Both frequency extremes and power. Selection must cover reliable low-wind triggering and maximum operating frequency; battery designs must account for average sensor and pull-up power.

FAQ

Low-wind readings are low or absent — what should I check first?
Check for dry bearings or deformed cups first, then the magnet-to-Hall air gap.
Pulses are lost and wind speed reads low at high wind — what should I do?
Check sensor maximum operating frequency and controller filter time, and whether cable length and pull-up slow the edges.
It fails after rain or damp conditions — what could cause it?
Usually cavity sealing, potting or wire-entry issues; condensation lowers insulation or causes Hall output faults.
The reading fluctuates periodically — how should I troubleshoot?
Cup imbalance, bearing wear or mounting-pole sway cause periodic changes; rule out mechanical causes, then check magnet eccentricity.
Battery life is short — what should I do?
Check continuous Hall and pull-up current; consider intermittent supply or low-power sampling.
Angle Position SensingRotation and angular displacement measurement with analog angle output.

Angle position sensing typically mounts a radially magnetized magnet on the shaft end face and a linear Hall sensor on the housing end face, coaxially opposed. As the shaft rotates the field direction changes continuously and the Hall output voltage varies with angle. The controller can convert angle by table lookup, or place Hall sensors in two orthogonal directions for sine/cosine solving to obtain a more stable angle.

Angle feedback: radial magnet + Hall
Applicable types
Linear analog
Operating temperature
-40~85°C
Supply voltage
5 V
Output
Analog voltage
AEC-Q100
Not required
Operating environment
Industrial rotation/angular-displacement measurement with possible vibration, dust and electromagnetic interference; usually 5 V or 24 V industrial supply.
Confirm before selection
Angle range (0~360° or small angle); angle resolution/accuracy; magnet type, size and mounting air gap; analog voltage or PWM/digital output and supply voltage.

Key points

  • Coaxiality. Eccentricity produces an angle-periodic error, so the structure must first ensure magnet-to-Hall coaxiality.
  • Air gap and mechanical play. Too large an air gap reduces amplitude and amplifies noise; shaft play and bearing clearance turn directly into reading error.
  • Interference and ferrous parts. PWM interference near motors requires shielding, grounding and sensible filtering; ferrous parts near the magnet change the field distribution.

FAQ

Angle reading fluctuates periodically — what should I check first?
Check magnet-to-Hall coaxiality, shaft play and whether the air gap changes during rotation.
Linearity is poor over the full turn — what should I do?
Confirm magnet magnetization direction and chip position; consider sine/cosine dual-Hall solving.
It jumps near the zero crossing — what could cause it?
Check signal amplitude, filter settings and grounding, and rule out motor PWM interference.
Power-up angle does not match reality — how should I troubleshoot?
Check the mechanical zero and calibration table; incremental schemes also need a homing procedure.
Deviation after replacing the shaft or housing — what should I do?
Check magnet mounting angle and air gap, and recalibrate against the original calibration points.
Clamp Meter Current SensingNon-contact conductor current measurement in clamp meters.

The core of an open-loop clamp meter is a gapped magnetic core: the measured conductor passes through the centre, the field produced by the current is concentrated into the gap, and a Hall element in the gap converts flux density into a millivolt-level voltage that is amplified, temperature-compensated and digitized into a current reading. The core provides flux concentration and scaling; gap dimensions, core material and assembly consistency directly set range and linearity.

Open-loop clamp meter: core concentrates flux; Hall measures it
Applicable types
Current sensor
Operating temperature
-20~85°C
Supply voltage
Battery
Output
Analog voltage
AEC-Q100
Not required
Operating environment
Handheld portable instrument, battery-powered, indoor/outdoor field measurement at ambient temperature; low power and interference immunity required.
Confirm before selection
Measured current range and accuracy; open-loop or closed-loop jaw (zero-flux feedback); battery or external supply and voltage; analog voltage or digital/ADC output; operating temperature range.

Key points

  • Jaw face fit. The two mating faces must be flat and clean with no visible gap when closed, otherwise the zero point shifts.
  • Conductor centering and zeroing. An off-centre conductor changes the magnetic path; zero the meter with no current before measurement.
  • Front-end stability. Amplifier zero, gain and reference voltage all enter the reading, especially at low battery.

FAQ

The reading is not zero with no current — what should I check first?
Check that the jaws close completely and the faces are free of rust or grease, then re-zero following the meter instructions.
Readings are low and non-linear at high current — what causes it?
The core may be saturating or the Hall sensor may exceed its linear range; check range and core cross-section. An off-centre conductor can look similar.
The reading jumps and repeatability is poor — what should I do?
Check jaw closure, other current-carrying conductors or strong magnets nearby, and keep signal wires away from power wires.
Accuracy degrades at low battery — what should I do?
The analog front end depends on a stable supply; replace the battery before deciding the meter is faulty.
The reading is abnormal after a drop or near a strong magnet — what should I do?
The core may retain remanence; demagnetize or replace the jaw assembly, then re-zero.
Electromagnet Field MonitoringContactless monitoring of electromagnet field strength and system performance.

Electromagnet field monitoring uses a linear Hall sensor to measure flux density at the pole face or in the air gap, indirectly reflecting excitation current, holding force or magnetization state. The sensor is usually mounted at the pole face, gap edge or near the workpiece, and its output is calibrated to field strength. Compared with current measurement, field monitoring reflects the magnetic circuit — for example gap changes, workpiece material differences or partial coil faults.

Gaussmeter probe: Hall element converts flux density to voltage
Applicable types
Linear analog
Operating temperature
-40~85°C
Supply voltage
5 V
Output
Analog voltage
AEC-Q100
Not required
Operating environment
Industrial site near an electromagnet with strong fields and electromagnetic interference; possible vibration and dust; contactless long-term stable operation.
Confirm before selection
Field range to be measured (mT); analog voltage or digital output and interface level; 5 V or 3.3 V supply; mounting position, gap to the electromagnet and temperature environment.

Key points

  • Relative position. Distance and orientation between Hall sensor and pole must be fixed; too close exceeds the linear range, too far gives a weak and interference-prone signal.
  • Orientation and batch consistency. The Hall plane must match the field direction; reversed or tilted mounting reads only a smaller component. Fixtures and fixing must be consistent in production.
  • Temperature rise and external fields. Electromagnet heating changes both flux and Hall zero, and nearby electromagnets, motors and ferrous structures add external fields.

FAQ

The reading does not change when energized — what should I check first?
Check Hall orientation, supply and signal line, and confirm the probe is not reversed or off the pole.
The reading saturates at high current — what should I do?
Reduce the sensed field, adjust probe position or use a larger range to stay within the linear region.
There is a large reading at no load — what could cause it?
It may be remanence or a nearby external field; demagnetize or compensate the zero.
The reading drifts as temperature rises — how should I troubleshoot?
Distinguish flux change from Hall drift, and compensate or recalibrate over the operating temperature range.
Batch-to-batch assembly consistency is poor — what should I do?
Check probe position, air gap and fixing fixture, and calibrate each monitoring point.
Gaussmeter Field MeasurementHall-element probes for gaussmeters and other magnetic-field measurement instruments.

A gaussmeter places a Hall element at the probe tip; when the field passes through the element it produces a Hall voltage, and the instrument amplifies, digitizes and calibrates it to display flux density. The probe should be as small as possible to minimize disturbance of the measured field, and the element position relative to the probe housing must be fixed, otherwise each insertion or mechanical load changes the effective measurement point. Soft-potted probes suit narrow spaces, but their leads and package are more sensitive to mechanical stress.

Gaussmeter probe: Hall element converts flux density to voltage
Applicable types
Linear analog, Hall element
Operating temperature
-40~85°C
Supply voltage
Instrument supply
Output
Analog voltage
AEC-Q100
Not required
Operating environment
Industrial instrument probe at ambient to moderate temperature; soft-potted probes need light vibration and moisture protection; usually powered from the instrument.
Confirm before selection
Field range (mT/G) and accuracy; soft or hard package and size limit; supply and output form (voltage/current/differential); temperature range and cable length.

Key points

  • Fixed effective measurement point. The probe must be small to reduce field disturbance, and the element-to-housing position must be fixed; insertion or mechanical load changes the measurement point.
  • Zero-field adjustment and orientation. Zero the probe in a zero-field environment before measurement, and keep the sensing face perpendicular to the field; wrong orientation reads low or even zero.
  • Ferrous tools and temperature drift. Ferrous tools and structures near the probe change field-line distribution, and temperature changes cause zero and sensitivity drift; high-accuracy use needs periodic calibration against a standard field.

FAQ

The reading drifts slowly — what should I check first?
Check warm-up time and ambient temperature, then zero the probe; Hall element and amplifier drift are the main sources.
The reading does not return after approaching a magnet — what could cause it?
The probe or nearby ferrous parts may be magnetized, or the amplifier may be saturated beyond range; move away and re-zero.
The reading is clearly low or reversed — how should I troubleshoot?
Check that the sensing face is perpendicular to the field, and whether the probe is installed backwards.
The reading jumps and is noisy — what should I do?
Check for an overlong probe lead or routing parallel to power cable, confirm shielding and grounding; an internal break in a soft-potted probe can also cause intermittent jumps.
A fixed offset remains after calibration — what should I do?
Confirm the calibration field covers the actual range, and that probe position in the fixture matches the calibration position.
Linear Position SensingContinuous linear displacement measurement with an analog or digital output proportional to travel.

Linear position sensing fixes a magnet to the moving part and a linear Hall element to the frame; as the magnet moves, the field at the element changes and the output follows an analog curve related to displacement. The controller does not use the whole curve directly but selects the section with the best linearity as the effective travel, with limits or software clipping at both ends. Magnet magnetization direction, size and motion path determine the curve shape; calibration only makes sense once the structure is fixed.

Linear Hall: field varies with displacement → analog voltage
Applicable types
Linear analog, Hall element
Operating temperature
-40~85°C
Supply voltage
5 V
Output
Analog voltage
AEC-Q100
Not required
Operating environment
Industrial site at ambient to moderate temperature with possible vibration and dust; long-term stable operation required.
Confirm before selection
Displacement range and resolution; linearity/accuracy; magnet type and mounting air gap; analog voltage or digital/PWM output.

Key points

  • Motion parallel to the sensing face. The magnet path should follow the Hall sensing face, with the air gap as constant as possible over the effective travel.
  • Avoid saturation and weak-signal ends. At both ends the magnet must not enter saturation or move so far that the signal becomes too small; only the effective section is linear.
  • Tolerance, thermal expansion and analog immunity. Frame tolerance, assembly clearance and thermal expansion change the air gap; shield the analog output and keep it away from motors and drives.

FAQ

The reading is inaccurate and the curve bends at both ends — what should I do?
The magnet is entering the non-linear or saturated region; narrow the effective travel, adjust the air gap and recalibrate the linear section.
The reading jumps in the middle — what should I do?
Check magnet-to-Hall parallelism, rail clearance and structural vibration; magnet tilt changes the air gap.
Zero shifts when temperature rises — what should I do?
Confirm stable sensor supply first, then consider temperature compensation or periodic zeroing.
Repeat positioning accuracy is poor — what should I do?
Rule out mechanical backlash, rail wear and a loose magnet, then check that calibration points cover the actual range.
Output noise is high — what should I do?
Check supply ripple, signal routing and grounding, and keep analog signals away from high-current wiring.
Magnetic EncoderAngle/position encoding with a magnetic ring for position and speed feedback.

A magnetic encoder consists of a magnet and Hall elements: the magnet is fixed to the rotating shaft and the Hall sensor is fixed nearby, contactless. Absolute angle usually uses a radially magnetized cylindrical or ring magnet with a linear Hall sensor, producing a continuous output with rotation angle. Incremental counting uses a multi-pole ring with bipolar latch Hall sensors; alternating poles flip the output, and two Hall sensors at an angular offset allow phase comparison and direction detection.

Angle feedback: radial magnet + Hall
Applicable types
Linear analog, Bipolar latch
Operating temperature
-40~85°C
Supply voltage
5 V
Output
Analog voltage, Digital latch
AEC-Q100
Not required
Operating environment
Industrial site with contactless ring coupling, vibration, oil and dust; electromagnetic interference immunity required.
Confirm before selection
Ring diameter and pole pairs; mounting air gap/concentricity; analog angle signal or latch pulse output; temperature range and supply voltage.

Key points

  • Coaxiality and air gap. Magnet eccentricity, shaft radial runout or bearing play change the duty cycle and distort the angle curve; rings with small pole pitch are more prone to missed pulses.
  • Cleanliness between magnet and Hall sensor. Iron filings on the ring change the local field, and oil and dust also need protection.
  • Avoid motor fields and power-line interference. Keep the Hall sensor away from the motor end, route signal wires away from power wiring, and verify the quadrature phase relationship.

FAQ

Counts are lost and speed feedback shakes at high speed — what should I do?
Check Hall maximum operating frequency and controller input filtering, and whether ring eccentricity or air gap is excessive.
Direction is occasionally misjudged — what should I do?
Check the relative angle, mounting height and phase consistency of the two Hall sensors, and confirm quadrature layout and cable shielding.
The angle curve is distorted at the ends or in one section — what should I do?
This is usually magnet misalignment, uneven ring magnetization or nearby ferrous structure; adjust coaxiality and air gap, and replace the magnet if needed.
It gradually fails in oil and iron-filing environments — what should I do?
Iron filings and oil sludge change the field distribution and increase the effective air gap; improve protection and cleaning.
Zero or angle deviates with temperature — what should I do?
Magnet flux and Hall zero change with temperature; add temperature compensation or periodic zeroing where accuracy matters.
Magnetic Flux MonitoringSensitive flux monitoring for isolated measurement of system performance.

Magnetic flux monitoring usually does not measure flux directly: the quantity to be monitored is first converted into a magnetic field — current through a flux-concentrating ring or coil produces a field, mechanical displacement changes a magnetic-circuit gap, and a Hall sensor reads that field as a voltage. The measured circuit and the signal side have no electrical connection, making this suitable for isolated measurement and condition monitoring. The linear Hall output is approximately proportional to flux density, a common choice for such schemes.

Gaussmeter probe: Hall element converts flux density to voltage
Applicable types
Linear analog, Current sensor
Operating temperature
-40~85°C
Supply voltage
5 V
Output
Analog voltage
AEC-Q100
Not required
Operating environment
Industrial site with isolated measurement, possible electromagnetic interference and vibration; wide ambient temperature.
Confirm before selection
Flux/current range and accuracy; required isolation voltage class; 5 V or other supply; analog voltage, current loop or other output.

Key points

  • Fixed magnetic circuit and uniform position. Place the Hall sensor where the gap field is uniform; gap width, ring opening and chip position must be stable after assembly.
  • Eliminate bypass paths and off-centre conductors. Ferrous brackets, screws or metal housings change field-line paths, and an off-centre conductor also shifts the reading.
  • Range saturation and drift. Beyond the linear range the reading clips, and permanent-magnet flux as well as chip zero drift with temperature.

FAQ

Zero drifts with temperature — what should I do?
Distinguish permanent-magnet flux change from chip zero drift; perform multi-point calibration over the operating temperature range.
At high current the reading grows slowly or stops changing — what should I do?
Check whether the magnetic circuit saturates or the Hall sensor exceeds its linear range; increase the air gap or change the range if needed.
The reading is affected by nearby equipment — what should I do?
Check nearby motors, relays, transformers and ferrous structures, and confirm the magnetic circuit is not bypassed.
Batch consistency is poor after assembly — what should I do?
Check Hall position in the gap, ring opening size and conductor centering, and calibrate each unit.
Deviation grows after long operation — what should I do?
Check magnet demagnetization, structural loosening and adhesive aging, then decide whether recalibration is needed.
Multi-Turn PositionAbsolute position detection across multiple revolutions.

Multi-turn position detection answers two questions: which turn the axis is on, and what angle it is at within that turn. A common approach uses a linear Hall sensor on the main-shaft end magnet for 0~360° single-turn angle, then a reduction gear train drives a final-stage magnet whose Hall sensor counts once per revolution to accumulate turns. Bipolar latch Hall sensors can also count main-shaft revolutions directly, combined with single-turn angle solving. The former is more complex but may retain turn information through power loss; the latter relies more on software bookkeeping.

Multi-turn position: Hall reads single-turn angle; a reduction gear counts turns
Applicable types
Bipolar latch, Linear analog
Operating temperature
-40~85°C
Supply voltage
5 V
Output
Digital latch, Analog voltage
AEC-Q100
Not required
Operating environment
Inside industrial equipment at ambient to moderate temperature with motor vibration, oil and dust; not automotive grade and no waterproof requirement.
Confirm before selection
Turn range and resolution; ring multi-pole or radial magnet and pole pairs; mounting air gap and eccentricity; digital latch counting or analog angle signal and interface level.

Key points

  • Gear backlash and accumulated error. Backlash causes small lost steps when reversing, accumulating into turn error over repeated cycles; gear wear and lubrication also change the transmission ratio.
  • Check the full-travel joint. After assembly, reciprocate in both directions to verify accumulated turns, and confirm that single-turn angle and turn-transition points join smoothly.
  • Power-loss memory design. Schemes without an absolute reference must home after power-up; with backup power or non-volatile storage, confirm the power-down write timing and battery life.

FAQ

Turn count deviates after reversing — what should I do?
Check gear backlash, ratio settings and counting edge, and estimate accumulated error after repeated reversals.
Power-up position is wrong — what should I do?
Confirm whether a mechanical zero or backup power exists, and check the homing procedure and stored turn count validity.
Single-turn angle and turn count jump at the transition — what should I do?
Check the mounting angle and zero of both sensors, and confirm the boundary conditions of the switching logic.
Turns are lost after long operation — what should I do?
Check gear wear, a loose magnet and the storage battery condition.
Occasional over-counting under vibration — what should I do?
Check debounce settings, magnet fixing and cable shielding, and exclude interference pulses.
Medical / Scientific Magnetic ImagingSpatial magnetic-field imaging in medical and scientific instruments.

Magnetic spatial imaging is essentially point-by-point field measurement. A linear Hall sensor outputs an analog voltage proportional to the field component; a probe scans a set path, the voltage is collected at each position, and the field distribution is reconstructed from probe orientation and calibration coefficients. A common structure mounts the Hall chip at the tip of a slender probe, sends the signal through shielded cable to a low-noise amplifier and ADC, and uses a motion stage for positioning.

Gaussmeter probe: Hall element converts flux density to voltage
Applicable types
Linear analog
Operating temperature
-20~85°C
Supply voltage
5 V
Output
Analog voltage
AEC-Q100
Not required
Operating environment
Inside or near medical/scientific instrument probes at ambient indoor temperature with low vibration; low noise, high linearity and low drift required.
Confirm before selection
Field range (mT/Gs) and resolution; probe-to-source spacing/air gap; supply and output interface (analog/differential); temperature range and accuracy/drift requirements.

Key points

  • Orientation and positioning. The probe axis must align with the measured field component and the distance must be fixed; scan-stage repeatability error goes directly into the image.
  • Power and shielding. The Hall output is a small signal; supply ripple, ground noise and signal shielding all raise the noise floor.
  • Range and thermal drift. The range must cover the maximum field with margin; for long measurements, monitor temperature or zero periodically.

FAQ

The reading drifts slowly — what should I check first?
This is usually temperature change or unstable supply; re-zero and temperature-compensate, then check supply ripple.
Local readings saturate — what should I do?
The probe range is insufficient or the probe is too close to the source; change the range or increase the distance.
Noise is high and detail is unclear — what should I do?
Check signal shielding, grounding and ADC reference voltage, and shorten the probe-to-amplifier distance.
Repeated scans do not match — what causes it?
The scan stage has insufficient positioning repeatability, or probe orientation changes during movement.
Zero shifts after the probe approaches a strong magnet — what should I do?
Magnetization or remanence may be present; demagnetize and recalibrate following the procedure.
Energy Storage BMS Current SensingCharge/discharge, over-current and isolated current sampling for energy-storage cabinets, battery packs and BMS.

Energy-storage cabinets and battery packs measure charge/discharge current for SOC estimation, over-current protection and short-circuit detection. A Hall current sensor converts the field around a busbar or PCB trace into a voltage, isolated from the high-voltage circuit and without the insertion loss and heating of a shunt. Small-current or board-level detection can use a linear Hall sensor with a U-shaped flux concentrator, while high-current busbars usually use a sensor module with a core.

Hall current sensing: primary current → flux → isolated output
Applicable types
Linear Hall, Current sensor
Operating temperature
-40~85°C
Supply voltage
5 V
Output
Analog output
AEC-Q100
Not required
Operating environment
Inside energy-storage cabinets/battery packs with temperature variation, high busbar current and strong electromagnetic interference; electrical isolation required.
Confirm before selection
Range and over-current multiple; accuracy and bandwidth; busbar structure and mounting space; isolation withstand voltage; bidirectional current and alarm threshold.

Key points

  • Mounting position. Avoid other phase conductors and high-current loops; busbar routing and nearby conductors add to the measurement.
  • Air gap and centering. The core gap must be fixed and the busbar must not be off-centre, otherwise sensitivity changes.
  • Range and isolation. Bidirectional output must cover positive and negative current; check range, bandwidth, drift and isolation withstand against the protection strategy.

FAQ

Zero drifts with temperature — what should I check first?
Confirm sensor temperature compensation is active, then check for a temperature gradient at the mounting position.
The reading saturates at high current — what should I do?
The range or core is too small; recalculate for maximum current and over-current multiple.
Adjacent phase conductors interfere — what should I do?
Increase busbar spacing or change sensor orientation, and use shielding or a differential structure if needed.
The reading changes after vibration — what causes it?
The busbar or sensor has loosened and changed relative position; add anti-loosening and retighten.
Protection actions are inconsistent — what should I do?
The Hall sensor only measures; over-current protection should form a multi-level scheme with fuses, contactors and software thresholds.
Current SensingNon-contact Hall current measurement in conductors or PCB traces for over-current protection and closed-loop control.

Hall current sensing uses the field around a current-carrying conductor: the conductor passes through a flux-concentrating ring and a Hall sensor in the ring gap outputs a voltage approximately proportional to primary current. An open-loop design is simple and low-cost, suitable for over-current protection and general closed-loop control; a closed-loop design uses a compensation coil to cancel flux, giving better linearity and drift for higher-accuracy use. PCB traces also produce measurable fields but the signal is weak, requiring close proximity and good shielding.

Hall current sensing: primary current → flux → isolated output
Applicable types
Current sensor, Linear analog, Hall element
Operating temperature
-40~105°C
Supply voltage
5 V
Output
Analog voltage, Current, Differential
AEC-Q100
Not required
Operating environment
Power/industrial distribution, VFD and inverter cabinets with high voltage, high current, strong electromagnetic interference and temperature rise; non-contact isolated measurement with response times down to microseconds.
Confirm before selection
DC, AC or pulse current, range and overload multiple; required response/bandwidth (microsecond level, 50 A/µs rise rate); voltage, current or differential output and accuracy/linearity; through-hole, PCB-mount or clamp-on installation and isolation voltage class.

Key points

  • Centering and turns. The conductor must pass through the ring centre, and the number of turns and winding direction must match the sensor ratio.
  • Ring gap. No ferrous foreign objects at the gap; nearby relays, transformers and high-current wires introduce external fields.
  • Range and bandwidth. The ring saturates beyond range; PWM current contains high-frequency components, and insufficient bandwidth clips or delays the waveform.

FAQ

Output is not zero at no load — what should I check first?
Check zero drift, assembly stress and external fields, and confirm no ferrous parts are near the ring gap.
Output saturates at high current — what should I do?
Check range and turns; increase the ring gap or use a larger-range sensor if needed.
The reading is affected by adjacent conductors — what should I do?
Review wiring, keep other high-current conductors away from the ring, and add shielding or change orientation if needed.
PWM current waveform is distorted — what causes it?
Check bandwidth, sampling instant and filter settings, and avoid treating switching ripple as average current.
Accuracy changes with temperature — what should I do?
Review zero and gain drift, and calibrate near the actual operating temperature.
Inverter Phase Current MeasurementDC bus, half-bridge emitter and output phase current measurement for inverters.

An inverter needs to measure three types of current: DC+ and DC- bus current, half-bridge low-side emitter current, and output phase current. A Hall current sensor concentrates the field from primary current into a core gap, reads it with a Hall element and converts it to a voltage; the signal side has no direct electrical connection to the power side. Compared with a shunt resistor, the Hall design does not insert a large resistor into the power loop and avoids the shunt's losses and common-mode issues.

Hall current sensing: primary current → flux → isolated output
Applicable types
Current sensor
Operating temperature
-40~125°C
Supply voltage
5 V
Output
Analog voltage, Current
AEC-Q100
Not required
Operating environment
Inside inverter/powertrain electrical components with high busbar common-mode voltage, high current, strong electromagnetic interference and vibration; electrical isolation required.
Confirm before selection
DC bus, bridge-arm or phase current and range; isolated or non-isolated and isolation withstand; analog voltage, current loop or PWM output and accuracy/bandwidth; supply voltage and mounting method (through-hole/PCB).

Key points

  • Measurement position and through-conductor. Bus, low-side arm and phase current use different through-conductor methods; keep the conductor centred and the turns and direction consistent.
  • Bandwidth and ground layout. Switching frequency is high and the waveform contains high-frequency components; bandwidth, sampling and ground layout must match.
  • Drift and safety. Zero/gain drift affects control; power-side to signal-side creepage must follow the product safety design.

FAQ

Current reads non-zero at no load — what should I check first?
Check zero drift and supply first, then external fields or adjacent phase conductors.
The reading jumps or spikes under load — what should I do?
Confirm sensor bandwidth, filter settings and ground layout, and rule out PWM switching-noise coupling.
Output saturates at high current — what should I do?
Check range, turns and whether the core saturates; reduce turns or use a larger range if needed.
Three-phase currents are asymmetric — what causes it?
Check each phase sensor's mounting direction, ratio and calibration coefficient, and confirm through-conductor positions are consistent.
Control performance changes with temperature — what should I do?
Review zero and gain drift, and confirm calibration was performed near the actual operating temperature.
Isolated MeasurementElectrically isolated current and signal measurement through magnetic coupling.

Isolated measurement addresses electrical isolation between a high-voltage/high-current primary side and a low-voltage secondary circuit. A Hall design uses the magnetic field as the intermediate quantity: the measured current produces flux in a core, a Hall sensor in the gap converts flux into a voltage, and signal conditioning outputs a voltage or current proportional to primary current. There is no direct electrical connection between primary conductor and secondary circuit; insulation is provided by the core, potting and structural distances. Open-loop is simple and suits general monitoring and protection; closed-loop uses a compensation coil to cancel flux, offering different linearity and drift for higher-accuracy metering.

Isolated measurement: primary current couples via flux; secondary output is isolated
Applicable types
Current sensor, Linear analog
Operating temperature
-40~105°C
Supply voltage
5 V / ±15 V
Output
Analog voltage, Current
AEC-Q100
Not required
Operating environment
Next to high-current busbars or rectifier sets in power, metallurgy, chemical, superconducting and high-energy-physics installations with strong fields, wide dynamic range, low impedance, possible surge and reverse short-circuit current; industrial vibration and EMI.
Confirm before selection
AC or DC, rated and maximum current and dynamic range; single-turn through-hole or multi-turn/openable core and aperture/conductor size; output form (voltage/current/transmitter interface), accuracy, linearity and response bandwidth; supply, temperature range, and reverse-current protection contacts or limit alarms.

Key points

  • Through-conductor and mating faces. Center the conductor and keep turns and direction consistent; foreign matter on an openable core's mating faces changes the air gap.
  • Insulation and wiring. Core, potting and structural distances together determine insulation; keep signal wires away from primary high-current wiring.
  • Range and drift. A large range often sacrifices resolution; check zero and gain drift together with isolation withstand.

FAQ

Output is not zero at no load — what should I check first?
Zero-calibrate first, then check mounting stress, temperature drift and nearby external fields.
Output is non-linear or saturates at high current — what should I do?
Check range, whether the core saturates, and the number of through-turns.
The reading changes with vibration — what causes it?
Check the mating faces, air gap and fixing of the openable core.
Output drifts after temperature rise — what should I do?
Review zero and gain drift, and confirm the calibration temperature is close to the actual condition.
Strong site interference and a jumping reading — how should I troubleshoot?
Check shielding and grounding, signal routing and isolation withstand, and confirm the creepage between signal and power sides.

Typical Cases (1)

Project case references

Compiled from real application projects; confirm parameters against your structure and operating conditions.

Case reference

PV inverter & energy-storage BMS current sensing

Busbar copper passes through a flux-concentrating ring, and a linear Hall sensor in the ring slot samples current for isolated high/low-voltage measurement.

Energy Storage BMS Current Sensing

Case reference

AC charging pile residual-current (RCD) detection

The charging cable L/N conductors pass together through a flux-concentrating ring; a linear Hall sensor senses the differential leakage field and triggers trip protection.

Isolated Measurement

This page introduces common practices for this application and Ouzhuo's available models for preliminary evaluation. For final selection, share your structure, air gap and operating conditions with our engineers, who will help verify the parameters and provide samples and basic application guidance.