Hall sensor | Magnetic Sensor
Application Case

Servo Drive Phase Current Sampling

Published 2026-11-23

End product

Servo drives and inverters need to sample the motor's three-phase currents for FOC vector control.

How it works

The three-phase output copper bars pass through flux-concentrating rings, and linear Hall sensors in the ring slots sense the phase-current waveform and feed it back to the DSP/MCU.

Selection considerations

High PWM switching frequency requires fast response and wide bandwidth (>100 kHz), with low output distortion over temperature.

Ouzhuo solution

Linear Hall ICs with relatively high sensitivity and low hysteresis, outputting a voltage corresponding to phase current; bandwidth and accuracy are confirmed against the specification.

Typical structure and mounting notes

Servo drives and inverters sample the U/V/W phase currents for FOC vector control. A common approach passes each phase copper bar through a flux-concentrating ring and places a linear Hall sensor in the ring gap; the output is a voltage proportional to phase current, conditioned and fed to an ADC or DSP. To save sensors, controllers often sample two phases and calculate the third by Kirchhoff’s law. Compared with a shunt resistor, the Hall design has no insertion loss and makes isolation between signal side and power side easier.

Center the copper bars through the rings and keep the three phases consistent in direction and through-conductor method. The mating faces of an openable ring must fit together, and the zero should be recalibrated after repeated opening and closing. The Hall position in the gap is fixed by the structure, and vibration must not change the spacing. PWM switching frequency is high, so sensor bandwidth and sampling instant directly affect waveform quality; sampling is usually done at a fixed point in the switching period. Route signal wires separately from power wiring, and handle shielding and grounding according to the drive layout.

Cabinet temperature rise, electromagnetic interference and vibration all affect the reading. During selection, check range, bandwidth, zero and gain drift, and the insulation requirement between power and signal sides; a larger range often sacrifices small-current resolution. For a broader description of the structure and troubleshooting, see Inverter Phase Current Measurement; for VFD applications see AC Variable-Frequency Drive. Confirm the specific bandwidth, accuracy and isolation requirements against the drive specification.

FAQ

  • Current reads non-zero at no load: zero-calibrate first, then check mounting stress, temperature drift and nearby external fields.
  • Waveform is distorted or spiky under load: confirm bandwidth, sampling instant and filter settings, and check PWM noise and ground layout.
  • Output saturates at high current: check range, through-turns and whether the ring saturates; reduce turns or use a larger range if necessary.
  • Three-phase currents are asymmetric: check each phase sensor’s mounting direction, ratio and calibration coefficient, and confirm through-conductor positions are consistent.
  • Control performance changes after temperature rise: review zero and gain drift, and confirm calibration was done near the actual operating temperature.