APPLICATION DOMAIN
Smart Metering & Flow Measurement
Smart water/gas meter counting, anti-tamper detection, heat meters, electricity meter anti-open
Scope
Smart water meter dial counting, photoelectric/magnetic gas meters, ultrasonic/magnetic flow meters, anti-magnetic tamper detection (Anti-Tamper), heat metering, smart electricity meter anti-theft, industrial magnetic slag/oil level gauges, water quality sampling instruments, liquid level meters
Ouzhuo Solution
Select by parameter →| Model | Type | Temperature | Voltage | Package |
|---|---|---|---|---|
| OH9213 | Omnipolar & Micropower Hall IC | -40~125℃ | 1.65-6V | SOT23 / DFN2*2-3 / T-SOT-23-3 |
| OH9245-S | Omnipolar & Micropower Hall IC | -40~150℃ | 2.8~24V | SOT23-3 |
| OH9248 | Omnipolar & Micropower Hall IC | -40~85℃ | 2.5~5.5V | TO-92S |
| OH9253-S | Omnipolar & Micropower Hall IC | -40~85℃ | 2.5~6V | SOT23-3 |
| OH4913 | Omnipolar & Micropower Hall IC | -20~85℃ | 2.4-6V | TO-92S |
| OH3020 | Unipolar Hall IC | -40~125℃ | 4.5~24V | TO-92S |
| OH3144 | Unipolar Hall IC | -40~125℃ | 4~24V | TO-92S |
| OH495AOH496B | Linear Hall IC | -20~125℃ | 4.5-10.5V | SOT89 / TO-92S |
| OH49EOH49E-S | Linear Hall IC | -20~100℃ | 3.0-6.5V | SOT89 / SOT23 / TO-92S |
Application Focus
Flow MeteringPulse or speed detection of the impeller in water, gas and heat meters.
The core of flow metering is turning the rotation of an impeller or turbine into countable pulses. Water, heat and gas meters commonly embed one or more magnets in the impeller and place a switch-type Hall sensor outside the meter body wall; each time a magnet passes the sensing face the output produces one pulse. The controller multiplies the accumulated pulse count by the volume per pulse to obtain total volume, and derives instantaneous flow from pulse frequency. For higher resolution, use a multi-pole magnetic ring or distribute several magnets evenly around the circumference.
- Applicable types
- Omnipolar switch, Unipolar switch
- Operating temperature
- -20~85°C
- Supply voltage
- 3.3 V or battery; micropower sleep/wake may be required
- Output
- Digital switch
- AEC-Q100
- Not required
- Operating environment
- Inside water, gas and heat meters; ambient-temperature medium, possible moisture, often battery-powered with low quiescent current, and vibration from impeller rotation.
- Confirm before selection
- Pole and strength of the impeller magnet; mounting air gap and distance from the magnet to the Hall sensor; battery or 3.3/5 V supply and whether micropower sleep/wake is needed; switch pulse or latch commutation output.
Key points
- Magnet balance and symmetric layout. Place the magnets symmetrically and balance the impeller; otherwise vibration at high speed increases and pulse stability suffers.
- Magnetic wall and ferrous parts in the cavity. The plastic or thin metal wall adds to the air gap, and ferrous parts inside can divert flux; fix the Hall position structurally once chosen.
- Low-flow oscillation and debounce. At low flow the impeller oscillates; level-only detection double-counts, so debounce in software. Dual Hall or latch types can distinguish direction.
Recommended models
FAQ
- No metering at low flow — what should I check first?
- Check the magnet-to-Hall spacing and field strength first, then the impeller's starting flow and whether it is sticking.
- Total flow reads high or low — what should I do?
- Verify the pulses-per-revolution calibration, magnet count and debounce settings, and confirm that impeller oscillation is not counted twice.
- Pulses are lost after some time in service — what should I check?
- Check for magnet demagnetization or corrosion, and for moisture at the Hall solder joints and leads.
- Meters from the same batch read differently — what should I do?
- Check magnet mounting tolerance, air gap and sensitivity grading, and recalibrate each meter.
- The battery drains too quickly — what should I check?
- Check quiescent current, the output pull-up resistor and the controller wake-up frequency.
Liquid / Oil Level DetectionLevel detection for oil tanks, water tanks and reservoirs.
Liquid level in oil tanks, water tanks and reservoirs is commonly sensed with a magnet-equipped float and a Hall sensor: the float rises and falls with the level while the Hall sensor is fixed outside the tank wall or at the top of a guide tube, switching when the float reaches the set point. There is no direct electrical contact with the medium, making this suitable for high/low level alarms or simple position detection. For continuous level, multiple Hall switches can be arranged in steps, or a linear Hall sensor can read the float magnet's continuous displacement.
- Applicable types
- Omnipolar switch, Unipolar switch
- Operating temperature
- -40~85°C
- Supply voltage
- 24 V or 5/3.3 V depending on the system
- Output
- Digital switch
- AEC-Q100
- Not required
- Operating environment
- Industrial oil and water tanks; the sensor is mounted on the top or side wall and may be exposed to oil, water or vapor; oil/water and corrosion resistance required; outdoor or workshop temperature swings and possible pump or machine vibration.
- Confirm before selection
- Pole and strength of the float magnet; mounting distance/air gap and tank wall thickness; operating temperature and required IP protection; supply voltage and whether a switch or analog output is needed.
Key points
- Float must move freely. At high oil viscosity or low temperature the medium flows poorly; keep the guide rod vertical with a suitable clearance — too tight causes sticking, too loose lets the magnet drift off the Hall axis.
- Keep away from surface disturbance. Avoid the impact zones of the inlet and return ports; sloshing, foam and bubbles can make the output switch repeatedly.
- Media compatibility and explosion protection. The medium determines float material, seals and magnet coating; for flammable or explosive areas follow the certification of the complete instrument.
Recommended models
FAQ
- The low-level alarm comes and goes — what should I check first?
- Check whether the float is sticking, whether the liquid surface is sloshing, and whether the Hall sensor and float are still aligned.
- The alarm does not clear after refilling — what should I check?
- Check whether the float is held by bubbles or foam, whether the guide rod is deformed, and whether the magnet has detached.
- The response is slow at low temperature — what should I check?
- Check oil viscosity and float weight, and whether wax or contamination has reduced the guide clearance.
- The float sticks after long-term use — what should I check?
- Check compatibility of the magnet coating and float material with the medium, and clean deposits.
- Detection fails after replacing the tank — what should I check?
- Check tank wall thickness, float position and Hall mounting height; recalibrate the switching point if necessary.
Heat Meter Flow & Temperature MeasurementFlow pulse and temperature measurement in heat meters and heat cost allocators.
A heat meter consists of a flow-measurement unit, supply and return temperature sensors, and a calculator. The flow unit is often an impeller type: water drives the impeller, and a magnet on it produces pulses through a Hall sensor, with each pulse representing a fixed volume increment. The temperature sensors measure supply and return temperatures, and the calculator combines flow and temperature difference to obtain heat. The Hall sensor only converts flow into pulses; temperature is still measured by dedicated sensors.
- Applicable types
- Omnipolar switch, Unipolar switch
- Operating temperature
- -20~105°C
- Supply voltage
- 3.3 V or 5 V
- Output
- Digital switch
- AEC-Q100
- Not required
- Operating environment
- Inside the heat meter body; the medium is hot water that can exceed 90°C, with long-term humidity, condensation and water-flow vibration.
- Confirm before selection
- Where the Hall sensor is mounted in the meter body and whether it senses the impeller, gear or magnet; maximum medium and ambient temperature; 3.3 V or 5 V supply; pulse switch output or direction discrimination (dual channel or latch).
Key points
- Straight pipe section before the impeller. Leave enough straight pipe upstream so the flow is stable without swirl or bubbles; otherwise impeller rotation and pulse spacing become uneven.
- Air gap determined by the meter body. The gap between Hall sensor and impeller is set by the body structure and must remain stable after assembly; magnet eccentricity or impeller wear makes pulse spacing uneven.
- Long-term water quality and moisture. Scale, rust and debris change impeller and magnet drag; the Hall sensor and solder joints need moisture protection, and the body seal must withstand long-term water pressure.
Recommended models
FAQ
- Flow reading is low — what should I check?
- Check whether the impeller is stuck by scale or debris, whether the strainer is blocked, and whether the straight pipe section and installation direction are correct.
- Flow pulses are missing — what should I do?
- Confirm that the magnet has not detached and that the Hall-to-impeller gap has not changed; check the signal line and pull-up resistor.
- False metering with an empty pipe or bubbles — what should I do?
- This is impeller free-running; address it through installation position and air venting, not by the sensor alone.
- Supply/return temperature difference is abnormal — what should I check?
- Temperature is measured by dedicated sensors; check probe installation and pairing. The Hall sensor does not measure temperature.
- Measurement drifts after long-term use — what should I do?
- Recalibrate according to the verification procedure; inspect impeller wear, scale buildup and magnet demagnetization.
Power & Energy MeteringIsolated current sensing for watt measurement and electricity metering.
A common single-phase electricity meter passes the live conductor through a magnetic core and places a Hall sensor in the core gap, reading a magnetic field proportional to the primary current. The conductor does not enter the signal circuit; the metering side is isolated from the mains by the core, creepage distance and insulation structure. The Hall output feeds a metering chip, which also samples the voltage channel, multiplies the two for instantaneous power, integrates it into energy over time, and outputs it as pulses or over a communication interface.
- Applicable types
- Current sensor, Linear analog
- Operating temperature
- -20~85°C
- Supply voltage
- 5 V
- Output
- Analog voltage
- AEC-Q100
- Not required
- Operating environment
- Indoor, room-temperature AC mains circuits; the signal side must be isolated from the measured current; continuous long-term operation.
- Confirm before selection
- AC or DC measured current and rated/maximum current; required accuracy and linearity (metering class or indication class); isolated or non-isolated mounting and available space; supply voltage and output form (analog voltage/current or pulse).
Key points
- Centering of the primary conductor. Keep the conductor centered in the magnetic core; eccentricity distorts the field distribution and shows up directly as zero and gain error.
- Ferrous environment around the core. No ferrous foreign objects at the gap; relays, transformers and metal brackets also change the field path, so leave distance in the layout.
- Recalibration after potting stress. Potting compound cure and thickness introduce stress; zero and gain calibration should be repeated after potting is complete.
Recommended models
FAQ
- Zero drifts or there is a reading at no load — what should I check first?
- Check temperature change and assembly stress first, then whether ferrous parts or large-current conductors are near the core; drift after potting is often stress from compound shrinkage.
- The reading is low at small currents — what should I do?
- It may be below the sensor noise floor or resolution; check the range and gain settings, and confirm shielding and grounding.
- The reading is systematically high or low — what should I check?
- Verify the number of conductor passes, the calibration coefficient and the voltage-channel correspondence; for three-phase meters also check phase sequence and phase.
- Energy is recorded but no pulse is output — what should I do?
- Check pulse-output polarity, pull-up resistor and metering-chip configuration; a wrong optocoupler current-limiting resistor also causes missing pulses.
- External magnets near the meter cause abnormal metering — what should I do?
- A strong magnet changes the Hall bias and makes the result unreliable; add shielding or move the sensor away from accessible housing areas, and log the event.
Pulse CountingCounting magnetic pulses for metering, mileage and flow totals.
Pulse counting turns a physical quantity into a train of pulses and accumulates them: each time a magnet on a flow-meter impeller, water-meter gear, wheel or conveyor passes a Hall sensor, the output changes state; the controller counts the edges and multiplies by the quantity represented by one pulse to obtain the total. A switch-type Hall sensor is sufficient. The key factors are pulses per revolution, pulse spacing and signal quality.
- Applicable types
- Unipolar switch, Omnipolar switch
- Operating temperature
- -20~85°C
- Supply voltage
- 5 V, often battery-powered
- Output
- Digital switch
- AEC-Q100
- Not required
- Operating environment
- Water meters, gas meters, flow meters and other dial or gear counting applications; ambient-temperature medium, possible moisture and vibration; often battery or 5 V supplied with low-power and long-life requirements.
- Confirm before selection
- Air gap between magnet and Hall device and the magnet specification (material, size, field strength); maximum dial/gear speed or pulse frequency (sets response bandwidth and power); supply voltage and battery operation; ambient temperature and whether waterproof/dustproof potting is needed; package and mounting constraints.
Key points
- No missed or double counts. The magnet-to-Hall spacing must make every pulse clear, and adjacent pulses need enough low-level separation.
- Balance debounce against response speed. Choose the pull-up resistor and filter capacitor together: too much filtering loses high-speed pulses, too little can count interference as pulses.
- Power loss and data consistency. Equipment with cumulative totals needs a power-loss save strategy or redundant storage so pulses are not lost at power-down.
Recommended models
FAQ
- The count is low at high speed — what should I do?
- Check whether the filter capacitor and debounce time are too long, and whether the Hall response speed and pull-up resistor match.
- The count slowly increases when stationary — what should I check?
- This is usually interference pulses; check the pull-up resistor, routing and shielding, and whether a switching supply or relay is nearby.
- The total does not match actual usage — what should I check?
- Verify the quantity per pulse, edge setting and calibration coefficient, and confirm that no factor is missing or counted twice.
- Counting is abnormal after the magnet comes loose — what should I do?
- Check the magnet fixing; a changed air gap can reduce some pulse amplitudes below the threshold.
- The total goes backwards after a power loss — what should I do?
- Check the save interval and write strategy; add a backup supply or save key counts more frequently if needed.
Meter Cover-Open & Anti-Tamper DetectionCover-open and magnetic tamper detection for electricity, water and gas meters.
A meter cover is commonly fitted with a magnet on its inner side and a Hall sensor at the corresponding position on the main board; closing the cover brings the magnet near, opening it moves the magnet away. The controller reads the change, records the cover-open event and its time. Some designs add a second linear or switch Hall sensor to detect an external strong magnetic field; the two serve different purposes — one monitors cover position, the other checks whether the field is abnormal.
- Applicable types
- Omnipolar switch
- Operating temperature
- -40~85°C
- Supply voltage
- 3.3 V; mains or battery
- Output
- Digital switch
- AEC-Q100
- Not required
- Operating environment
- Inside the meter enclosure with long-term power, large temperature swings and high humidity; battery meters need very low quiescent current.
- Confirm before selection
- Meter power source (mains or battery); target service life; actuation distance for cover-open detection; whether external magnetic interference must be rejected; available space and potting requirements.
Key points
- Cover air gap affected by tolerances. Seal compression, latches and assembly tolerance all change the closed-cover air gap; the magnet and Hall sensor must face each other and stay stable.
- Does the housing material shield the field?. Metal or metal-coated housings shield magnetic fields; confirm the housing material before choosing the mounting position.
- Separate cover-open from strong-magnet interference. Cover position and external strong-field interference are different events; a dual-channel design must define each decision target and not merge them into one signal.
Recommended models
FAQ
- A normally closed cover reports open — what should I check first?
- Check whether the magnet has detached, whether the cover is fully seated, and whether seal compression has increased the air gap.
- The state does not change when the cover is opened — what should I do?
- Confirm Hall polarity and output-logic configuration, and check whether the housing contains metal that shields the field.
- An external magnet triggers a warning but the result is uncertain — what should I do?
- This is the normal behaviour of interference detection; set the threshold and event logging according to the meter specification.
- Power consumption is high after long service — what should I check?
- Check the sampling interval and sleep current, and avoid keeping the Hall sensor continuously active.
- Detection fails after replacing the cover — what should I do?
- Check that the new cover's magnet position and polarity match the original design, and recalibrate the switching point if needed.
Typical Cases (4)
Gas & Water Meter Anti-Tamper Magnetic Detection
Omnipolar Hall sensors around the meter housing detect an external strong magnetic attack and wake the MCU to record an alarm.
View Case →Heat Meters & Heat Cost Allocators
Heating water drives a magnetic impeller; the Hall sensor reads its speed and outputs flow pulses, which are combined with the supply/return temperature difference to calculate heat.
View Case →Smart Socket & PDU Power Monitoring
A linear Hall sensor beside the live/neutral conductor samples load current; voltage is combined to calculate real-time power and energy.
View Case →Smart Water Meter Dial Counting
Each pass of the impeller magnet produces a Hall pulse; the MCU accumulates pulses to calculate water consumption.
View Case →Project case references
Compiled from real application projects; confirm parameters against your structure and operating conditions.
Industrial magnetic flow meter
A float or gear magnet triggers a Hall sensor on the outside of the pipe wall, converting mechanical flow into frequency pulses.
Flow Metering
Intelligent liquid level & fluid detection
A float magnet moves with the liquid level; a linear Hall sensor reads its position through the wall and outputs a continuous level or flow signal.
Liquid / Oil Level Detection
Industrial level gauge & tank oil-level sensing
A magnetic float moves with the oil level; multiple Hall sensors along the outside of the measuring tube show stepped level readings by height.
Liquid / Oil Level Detection
Smart electricity meter cover-open sensing
A magnet at the cover seam and a Hall sensor in the meter body: unauthorized opening moves the magnet away and triggers a power-loss-stored alarm.
Meter Cover-Open & Anti-Tamper Detection
This page introduces common practices for this application and Ouzhuo's available models for preliminary evaluation. For final selection, share your structure, air gap and operating conditions with our engineers, who will help verify the parameters and provide samples and basic application guidance.