APPLICATION DOMAIN
Low-Power & Portable/Wearable
TWS charging cases, e-cigarettes, AR/VR glasses, smart watches, medical patches
Scope
TWS Bluetooth earbud charging-case open/close detection, e-cigarette draw/pod locking, smart watch/band wear detection, AR/VR glasses folding/face-mask sensing, portable blood glucose meters/patch medical clasps, tablet smart covers, Bluetooth headsets, shared power banks
Ouzhuo Solution
Select by parameter →| Model | Type | Temperature | Voltage | Package |
|---|---|---|---|---|
| OH9213 | Omnipolar & Micropower Hall IC | -40~125℃ | 1.65-6V | SOT23 / DFN2*2-3 / T-SOT-23-3 |
| OH9245-S | Omnipolar & Micropower Hall IC | -40~150℃ | 2.8~24V | SOT23-3 |
| OH9248 | Omnipolar & Micropower Hall IC | -40~85℃ | 2.5~5.5V | TO-92S |
| OH9253-S | Omnipolar & Micropower Hall IC | -40~85℃ | 2.5~6V | SOT23-3 |
| OH4913 | Omnipolar & Micropower Hall IC | -20~85℃ | 2.4-6V | TO-92S |
| OH3141E | Unipolar Hall IC | -40~125℃ | 4.5~24V | TO-92S |
| OH3020 | Unipolar Hall IC | -40~125℃ | 4.5~24V | TO-92S |
| OH49EOH49E-S | Linear Hall IC | -20~100℃ | 3.0-6.5V | SOT89 / SOT23 / TO-92S |
| OH41OH41A | Bipolar & Latch Hall IC | -40~150℃ | 4.5~ 24V | TO-92S |
Application Focus
Digital Camera & Camcorder Position DetectionPosition and angle sensing for folding screens, lens barrels and battery or card covers in cameras and camcorders.
Position sensing in digital cameras and camcorders is spread across several points: the folding and rotation of the monitor, lens-barrel extension, and the opening of the battery and memory-card covers all need end-position or angle signals. Folding covers only need open/close detection, which a unipolar or omnipolar switch can provide; when the fold angle or lens extension must be known, a linear Hall sensor outputs a voltage that varies with the field and the controller converts it into angle or displacement. A linear design approximates the field change as a straight line over a limited travel; outside the linear region the reading departs from the actual displacement.
- Applicable types
- Unipolar switch, Linear analog
- Operating temperature
- -20~85°C
- Supply voltage
- 3.3 V
- Output
- Digital switch, Analog voltage
- AEC-Q100
- Not required
- Operating environment
- Inside consumer electronics at ambient temperature, with low-power battery supply and compact space; no water or dust protection required.
- Confirm before selection
- Whether screen hinge/folding open-close position or continuous angle is detected; switch or analog output; magnet type and mounting air gap; 3.3 V or 5 V supply.
Key points
- Move the magnet along the sensing axis. In a linear design the magnet must move along the Hall sensing axis; lateral offset bends the curve, so calibration must cover both ends of the actual travel.
- Trigger before the mechanical stop. In a switch design the trigger point must come before the mechanical stop so the controller receives the signal before stopping the motor.
- Avoid internal magnetic sources and flex fatigue. Keep the magnet away from speakers, lens voice-coil motors and wireless-charging coils; a Hall sensor on a folding-screen flex must withstand long-term bending.
Recommended models
FAQ
- Folding-screen angle detection is inaccurate — what should I do?
- Check the relative position of magnet and Hall sensor and whether the linear region covers the full travel, then perform a two-point calibration.
- The screen does not respond after folding — what should I do?
- Check Hall solder joints and the flexible cable, and confirm the magnet has not detached or shifted.
- The output chatters at a critical angle — what should I do?
- Adjust the operating-point hysteresis, mechanical clearance or software hysteresis so the mechanism does not rest at the trigger boundary.
- Readings differ between units of the same model — what should I do?
- Check magnet insertion depth, incoming-part consistency and assembly tolerance.
- Drift appears after long-term use — what should I do?
- This is usually magnet demagnetization or structure wear changing the air gap; recalibrate and check the fixing method.
Docking DetectionDetecting whether two parts are docked or separated, such as a charging dock or module connector.
Docking detection determines whether two parts are connected in position, such as a charging dock and the device, a module and the host, or a handheld terminal and its cradle. A common approach mounts the magnet in the dock and the Hall sensor in the device, or vice versa; when docked, the magnet enters the sensing zone and the output changes, so the device switches charging, communication or operating state. An omnipolar switch does not care about magnet polarity, which simplifies production and after-sales.
- Applicable types
- Omnipolar switch, Unipolar switch
- Operating temperature
- -20~85°C
- Supply voltage
- Battery or low-voltage supply
- Output
- Digital switch
- AEC-Q100
- Not required
- Confirm before selection
- Mounting air gap and magnet size for dock/undock detection; permanent magnet or electromagnet and surface flux density; supply voltage and switch/level output; operating temperature and whether water/dust protection is needed.
Key points
- Alignment tolerance covers the actuation distance. Users place devices with lateral and angular offset; the actuation distance must cover normal offset while still releasing reliably when removed.
- Metal parts in the dock alter the field. Metal weights, shields and charging coils change the field distribution; leave distance between the magnet, the Hall sensor and these parts.
- Direction identification with multiple magnets. When orientation must be distinguished, magnet spacing and polarity must be reliably separable, and the charging contacts and Hall sensor should be offset to avoid blocking each other.
Recommended models
FAQ
- The device is placed on the dock but is not recognised — what should I do?
- Check whether magnet and Hall sensor are aligned, whether the air gap exceeds the actuation distance, and whether metal parts in the dock shield the field.
- The device is lifted but still shows docked — what should I do?
- Check whether the release point is too low, whether the magnet remains at the edge of the sensing zone, and the software debounce.
- Different devices are recognised inconsistently — what should I do?
- Check magnet mounting position and dock tolerance; adjust the operating point or use a linear Hall sensor for distance judgement.
- Faults after dust or water enters the dock — what should I do?
- Check cleanliness of the sensing surface, connector sealing and PCB protection.
- Charging works but the docking state is wrong — what should I do?
- Separate the charging contacts from the Hall signal, and check signal wiring and controller input configuration.
Handheld Wireless Device Wake-UpWake/sleep detection for handheld wireless devices.
Handheld wireless devices often need a "pick up to use, put down to sleep" trigger. A common design mounts a magnet in the handle, folding cover or button slider and a Hall sensor on the main board; when the magnet approaches, the output changes and the controller wakes, returning to sleep when it leaves. Some designs use magnet displacement to distinguish grip states, or a single Hall sensor for both power-on and sleep decisions.
- Applicable types
- Omnipolar switch, Unipolar switch
- Operating temperature
- -20~85°C
- Supply voltage
- 3.3 V
- Output
- Digital switch
- AEC-Q100
- Not required
- Operating environment
- Handheld wireless devices with battery power, low power consumption and indoor ambient temperature; light vibration possible.
- Confirm before selection
- Supply voltage; detection distance/field strength requirement; normally open or normally closed output; package constraints; whether low power is required.
Key points
- Standby current first. The device may sit unused for long periods; Hall operating current and sampling method directly affect battery life, so compare average rather than peak current.
- Tolerance at actuation and release. Housing deformation or magnet position error makes the wake distance unstable; the release distance must cover assembly tolerance.
- Debounce drop false triggers. When the magnet is on a moving part, a drop can momentarily cross the operating point; the software needs a short debounce period.
Recommended models
FAQ
- Standby time is noticeably shorter — what should I do?
- Measure the actual sleep current of the Hall sensor and controller, and check the sampling duty cycle and pull-up resistor.
- The wake distance varies — what should I do?
- Check magnet mounting position, housing tolerance and Hall bias, and retest the operating point with a fixed fixture.
- False wake-up on drop — what should I do?
- Check whether the software debounce is long enough and whether the magnet has come loose from impact.
- The cover state jumps — what should I do?
- Check whether magnet and Hall sensor are coaxial and whether hinge play causes periodic air-gap changes.
- It does not wake at low temperature or low voltage — what should I do?
- Check the Hall minimum operating voltage and operating-point temperature drift, and confirm supply design margin.
Laptop Lid Open/Close DetectionLid open/close detection for laptop sleep and wake.
Laptop lid detection uses a Hall switch to determine whether the screen is closed; the controller uses it to sleep, wake or turn off the backlight. The magnet is usually embedded in the screen bezel and the Hall switch is fixed near the main board or a secondary board in the base; closing the lid brings the magnet near and the output changes. Compared with a mechanical contact, a Hall sensor has no exposed button, does not fail from dust and wear, and consumes little power, making it suitable for long standby on battery.
- Applicable types
- Omnipolar switch, Unipolar switch
- Operating temperature
- -20~85°C
- Supply voltage
- 3.3 V
- Output
- Digital switch
- AEC-Q100
- Not required
- Operating environment
- Inside a battery-powered laptop at ambient temperature, with low power, tight space and light vibration.
- Confirm before selection
- Magnet-to-Hall mounting distance/air gap; magnet or magnetic ring and field strength; 3.3 V or 5 V supply and whether low-power sleep is needed; open-drain or push-pull output and polarity.
Key points
- Embedding depth and magnetization direction. Magnet embedding depth, magnetization direction and initial air gap together set the actuation angle; calculate them together with hinge and bezel tolerance.
- Avoid built-in magnet interference. Fields from speakers, keyboard magnets and wireless-charging coils can hold the switch triggered; evaluate the layout first.
- Standby power and sampling. Hall and pull-up standby current directly affect battery life; intermittent power must balance wake latency against duty cycle.
Recommended models
FAQ
- The lid closes but the laptop does not sleep, or opening does not wake it — what should I do?
- Check whether the magnet is reversed or missing and whether the initial air gap is too large, then confirm the board sees the switch state.
- A slight lid movement causes false sleep — what should I do?
- The operating point is too early or hysteresis too small; adjust magnet position and air gap, and add a confirmation delay or hysteresis in software.
- False triggers near the speaker or keyboard — what should I do?
- This is external magnet interference; adjust the Hall position, add magnetic shielding, or combine with screen-angle cross-checks.
- Standby power is too high — what should I do?
- Check whether Hall supply and pull-up resistor remain active in sleep, and switch to intermittent sampling if needed.
- Abnormal operation at high or low temperature — what should I do?
- Magnet flux and plastic dimensions change with temperature; calculate the worst-case air gap over the product temperature range.
Flip & Slide Phone Open/Close DetectionOpen/close detection for flip and slider phones, for screen wake or call hang-up.
A flip phone mounts the magnet at the edge of the upper (screen) half, while a slider phone mounts it on the sliding panel; the Hall switch sits on the main board near the hinge or slide rail. When closed, the magnet faces the Hall sensor, the field exceeds the operating point and the output changes; when opened, the magnet moves away, the field falls below the release point and the output returns. The controller reads this switch signal to wake or blank the screen or end a call. Most models need one detection point; some place one at each end of the travel to distinguish partly open from fully open.
- Applicable types
- Omnipolar switch, Unipolar switch
- Operating temperature
- -20~85°C
- Supply voltage
- 1.8 V or 3.3 V
- Output
- Digital switch
- AEC-Q100
- Not required
- Operating environment
- Inside a battery-powered phone at indoor ambient temperature; the flip/slide mechanism has light vibration, very tight space and high low-power requirements.
- Confirm before selection
- Magnet-to-Hall mounting air gap; magnet type (pole and field strength); 1.8 V or 3.3 V supply and low-power/sleep requirements; open-drain or push-pull output and required sensitivity (Bop/BRP).
Key points
- Relative position and actuation distance. The magnet is only a few millimetres; the air-gap margin must ensure triggering when closed while falling below the release point when opened.
- Avoid self-magnetic components. Speakers, vibration motors and autofocus motors add a bias to the detection field; keep distance in the layout.
- Stress and air-gap tolerance. Dispensing, overmoulding and housing clamping introduce stress, and drops or squeezing shift the two halves; leave tolerance in the air-gap design.
Recommended models
FAQ
- The screen does not blank or the call does not end after closing — what should I do?
- Check magnet-to-Hall spacing and polarity, then the Hall orientation, solder joints and whether the upper housing is deformed.
- It stays triggered after opening — what should I do?
- Check the release point and magnet distance, and confirm that speaker or motor magnets are not adding to the field.
- Standby current is high — what should I do?
- Check device quiescent current, the output pull-up resistor and the controller sleep strategy; switch to a lower-power model if needed.
- Sensitivity differs between phones of the same model — what should I do?
- Check magnet incoming consistency, assembly tolerance and stress after dispensing cure.
- Function is abnormal after a drop or squeeze — what should I do?
- Check chip solder joints, magnet displacement and air-gap changes from housing deformation.
Portable Game Console & Toy Position DetectionPosition and action detection in portable game consoles and toys.
Hall sensors in portable consoles and toys mostly determine the position of moving parts: whether a folding cover is closed, a slider is open, a cartridge bay is seated, or a joystick or button has returned to its rest position. A common design mounts a small magnet on the moving part and an omnipolar or unipolar switch on the main PCB; the output changes when the magnet approaches. An omnipolar switch does not care about magnet polarity, which simplifies assembly.
- Applicable types
- Omnipolar switch, Unipolar switch
- Operating temperature
- -20~85°C
- Supply voltage
- 3.3 V
- Output
- Digital switch
- AEC-Q100
- Not required
- Operating environment
- Handheld, battery-powered consumer devices indoors at ambient temperature; low power is a priority and drops/vibration are possible.
- Confirm before selection
- Magnet or coil trigger; detection distance/air gap; supply voltage and battery type; switch output or latched state.
Key points
- Package and standby current first. For compact, battery-powered handhelds and toys, start with package size, operating voltage and standby current.
- Housing and shields affect distance. Wall thickness, ribs and internal metal shields change the sensing distance; design magnet position around housing tolerance.
- Child safety and retention. Drops and repeated operation require reliable magnet fixing; where child safety applies, magnet size and fixing must meet the relevant standard.
Recommended models
FAQ
- Closing the lid does not sleep — what should I do?
- Check magnet-to-Hall alignment, whether housing tolerance has increased the air gap, and the sleep logic configuration.
- It wakes frequently without operation — what should I do?
- Check for nearby magnetic sources, magnet position shift and software debounce, and confirm drops do not cause false triggers.
- Slider position detection jumps — what should I do?
- Check whether the magnet rests at the edge of the sensing zone, and shift the magnet or add hysteresis.
- Function is abnormal after a drop — what should I do?
- Check whether the magnet has detached, solder joints have cracked and the housing is deformed.
- Battery life becomes shorter — what should I do?
- Check Hall standby current and sampling period, and confirm the device returns to low power promptly after wake.
Wearable Dock & Wear DetectionDock, lid and wear-state detection for smart watches, bands and earbud cases.
Wearable devices have very little space and short detection distances. A common design puts a small magnet on the earbud, watch body or case lid edge and a Hall sensor in the charging dock or host; docking or closing the lid brings the magnet near and changes the output state. An omnipolar switch is insensitive to magnet orientation, so assembly does not need to distinguish N/S poles, suiting high-volume, compact products.
- Applicable types
- Omnipolar switch
- Operating temperature
- -20~85°C
- Supply voltage
- 3 V
- Output
- Digital switch
- AEC-Q100
- Not required
- Operating environment
- Worn on the body and carried around; very tight space, small battery, sweat, temperature change and drops.
- Confirm before selection
- Battery capacity and target battery life; actuation speed (dock/lid); structure thickness and available magnet size; whether left/right earbud or wear direction must be distinguished; IP rating and housing material.
Key points
- Spacing and eccentricity determine consistency. The housing is thin, so the magnet must not sit too close to the surface; docking or closing must produce a stable trigger zone rather than a marginal touch.
- Evaluate stray fields. Earbud cases and watches may be near speakers, wireless-charging coils and magnetic accessories; assess whether they cause false triggers.
- Micropower and pull-up loss. Almost all designs use micropower omnipolar switches; average current, sampling period and continuous pull-up loss determine battery life.
Recommended models
FAQ
- The device is placed on the dock but is not recognised — what should I do?
- Check magnet-to-Hall distance and eccentricity, and confirm the housing thickness does not exceed the design value.
- The state jumps after closing or docking — what should I do?
- The magnet is resting at the threshold; adjust the mounting position or use hysteresis and software debounce.
- Battery life is noticeably shorter — what should I do?
- Check Hall sampling period and pull-up resistor; continuous supply drains the battery.
- False triggers near wireless charging — what should I do?
- The charging-coil field may interfere; adjust the Hall position or add a plausibility criterion.
- Failure after a drop or sweat exposure — what should I do?
- Check potting, the waterproof membrane and solder joints; water ingress causes leakage.
Infusion Pump Door & Flow DetectionDoor-closed, peristaltic rotor speed and occlusion detection for infusion and syringe pumps.
Infusion and syringe pumps usually use Hall sensors in two places. One detects whether the door is properly closed, with a magnet on the door edge and a Hall sensor inside the body. The other measures the peristaltic rotor speed, with a magnet or magnetic ring on the rotor and Hall pulses feeding the controller, which calculates actual delivered volume from the pulse count. The door signal decides whether pumping may start, while the speed signal drives the flow loop and occlusion detection; the two serve different purposes and cannot replace each other.
- Applicable types
- Bipolar latch, Linear Hall, Omnipolar switch
- Operating temperature
- -20~70°C
- Supply voltage
- 5 V
- Output
- Digital latch, Analog output
- AEC-Q100
- Not required
- Operating environment
- Hospital indoor use with low noise, low power and high reliability; surfaces are regularly cleaned and disinfected.
- Confirm before selection
- Pump type (peristaltic/syringe); flow range and resolution; door-detection actuation distance; battery backup and low-power mode; cleaning/disinfection method and housing material.
Key points
- Door trigger zone. Hinge wear changes the relative position of magnet and Hall sensor; leave a stable trigger zone after closing.
- Speed and metering. Magnet count, mounting angle and air gap must be fixed; missing pulses show up directly as a delivered-volume error.
- Cleaning and interference. The device must tolerate alcohol or chlorine disinfectants; when the motor is close to the Hall sensor, evaluate field interference and power consumption.
Recommended models
FAQ
- The door is closed but the pump says it is open — what should I check first?
- Check whether the hinge has sagged or the door seal has aged, increasing the magnet-to-Hall distance.
- Flow display does not match actual delivery — what should I do?
- Check whether speed pulses are missing, whether the magnet is loose, and whether the connector has poor contact.
- Abnormal after cleaning and disinfection — how should I troubleshoot?
- Confirm that liquid has not entered along pins or seams, and whether potting or the housing has cracked.
- False counting at motor start — what causes it?
- Motor fields or supply fluctuation can couple into the signal line; check routing and filtering.
- Battery backup time becomes shorter — what should I do?
- Check continuous current in the Hall sensor and pull-up, and whether the sleep strategy works as expected.
Medical Device Position DetectionEnd-position and continuous displacement/speed detection in medical equipment.
Medical equipment has two common position-sensing needs: "in position / not in position", such as confirming when a bed plate, tray, cover or insertion mechanism reaches its end point; and continuous displacement or speed feedback, such as on a slide table, syringe pump or lift mechanism. End-position detection can use an omnipolar or unipolar switch, while continuous displacement uses a linear Hall sensor with a magnet and an analog voltage output for the controller.
- Applicable types
- Unipolar switch, Linear analog
- Operating temperature
- -20~85°C
- Supply voltage
- Low-voltage DC
- Output
- Digital switch, Analog voltage
- AEC-Q100
- Not required
- Operating environment
- Inside medical equipment in a clean, ambient-temperature environment; periodic disinfection wiping, low vibration and usually low-voltage DC supply.
- Confirm before selection
- Whether end-position switch or continuous displacement/speed analog is needed; mounting air gap and magnet specification (size/field strength); supply voltage and output interface (switch/analog voltage/current); operating temperature and whether water/dust or disinfectant resistance is required.
Key points
- Travel and air gap. The air-gap change over the whole travel must stay within the device limit; the end-position magnet must not collide with the mechanical stop.
- Linear region. For continuous displacement, keep the magnet in the linear region and avoid saturation at both ends; provide strain relief for the leads.
- Sealing and failure analysis. Equipment is wiped with disinfectant, so cavities must resist cleaning liquids; patient-safety-related signals must not rely on a single Hall sensor alone.
Recommended models
FAQ
- Drift or false triggers after cleaning and disinfection — what should I check first?
- Check cavity sealing, potting and connectors for water ingress; if the fault persists after drying, check whether the magnet has rusted or been knocked out of position.
- Continuous displacement reads incorrectly at both ends — what should I do?
- The magnet is entering the non-linear or saturated region; narrow the effective travel, adjust the air gap and calibrate the end points.
- Magnets in adjacent mechanisms interfere — what should I do?
- Change magnet orientation, add shielding or increase spacing; in software, combine several sensors for a plausibility decision.
- The signal occasionally jumps — what causes it?
- Check whether the harness bends repeatedly with the moving mechanism and whether connectors are loose; cable fatigue is a common cause.
- Zero shifts with temperature — what should I do?
- Linear Hall zero and sensitivity change with temperature; where accuracy matters, add temperature compensation or periodic zeroing.
Typical Cases (2)
Tablet Smart Cover
A magnet in the cover flap triggers a Hall sensor at the tablet edge: opening wakes and unlocks, closing blanks and sleeps.
View Case →TWS Bluetooth Earbud Charging Case
A magnet in the earbud-case lid works with a miniature Hall sensor: opening the lid triggers pairing, closing it sleeps and charges.
View Case →Project case references
Compiled from real application projects; confirm parameters against your structure and operating conditions.
Smart watch/band wear & charging detection
A magnet in the clasp or charging dock triggers a Hall sensor, waking the charging UI and detecting wear state.
Docking Detection
Laptop and TWS earbud case lid detection
A magnet in the screen or earbud-case lid works with a miniature Hall sensor for lid-close sleep and lid-open wake / reconnect.
Laptop Lid Open/Close Detection
Foldable phone hinge-angle sensing
Magnets on the folding hinge rotate to change the field angle; a miniature linear Hall sensor tracks the screen fold angle in real time.
Flip & Slide Phone Open/Close Detection
Electronic blood pressure monitor & medical pressure sensing
Air pressure moves a diaphragm; a linear Hall sensor reads the field change and converts the small displacement into a pressure value.
Medical Device Position Detection
Portable blood glucose meter CGM patch
A magnet at the patch/transmitter clasp triggers a Hall sensor, activating the battery and starting Bluetooth transmission.
Medical Device Position Detection
Medical device safety limits
Infusion-pump pusher end stops and bed lift limits use contactless Hall limit sensing: spark-free, quiet and safe.
Medical Device Position Detection
This page introduces common practices for this application and Ouzhuo's available models for preliminary evaluation. For final selection, share your structure, air gap and operating conditions with our engineers, who will help verify the parameters and provide samples and basic application guidance.