Smart Socket & PDU Power Monitoring
Published 2026-11-23
End product
Smart metering sockets and PDU power strips need to monitor load power and energy in real time.
How it works
A linear Hall sensor with a flux-concentrating structure beside the neutral/live conductor samples load current; voltage is combined to calculate power and energy, and to cut off the load on overload.
Selection considerations
Internal space is too small for a current transformer, and good linear response is still needed at small currents (<100 mA).
Ouzhuo solution
Compact SOT-23 linear Hall ICs that occupy little PCB area, suited to space-constrained power monitoring; range and accuracy are confirmed against the complete product requirements.
Typical structure and mounting notes
A smart metering socket measures the AC current flowing in the live or neutral conductor inside the socket. A common approach places the conductor against or through a small flux-concentrating structure, with a linear Hall sensor in the gap. Its output is a voltage proportional to instantaneous current; the controller samples voltage and current together to calculate real power, power factor and accumulated energy, and opens a relay above a set threshold. Compared with a shunt resistor, the Hall approach has no insertion loss and makes isolation between the signal side and mains side easier.
Keep the conductor centered through the flux concentrator. Route three-phase or live/neutral pairs separately so the two wires do not cancel each other’s field. The Hall position in the gap is fixed by the structure and must not shift after assembly. Socket space is tight, and conductor bends and high-current traces add stray fields; keep the Hall sensor away from relay coils, transformers and adjacent socket wiring. Zero drift is the main error source, so production units usually need individual calibration.
Safety is critical in this product class: creepage distance, clearance and insulation thickness between the mains side and low-voltage side have explicit requirements, and the flux concentrator and Hall position must not reduce them. Check long-term operating temperature, load-current range and overload capability together. For a broader description of metering, see Power & Energy Metering; for the current-sensing principle, see Current & Position/Angle Sensing. Confirm the specific accuracy class and safety requirements against the applicable product standard.
FAQ
- Power reads non-zero at no load: perform zero calibration first, then check mounting stress, temperature drift and interference fields from nearby conductors.
- Large deviation at small currents: check the range, flux-concentrator structure and resolution, and confirm the calibration points cover the actual operating range.
- Reading saturates or jumps at high power: check whether the range is sufficient, whether the flux concentrator saturates, and the sampling-circuit supply.
- Readings interact between adjacent sockets: check magnetic coupling from adjacent conductors, adjust the Hall position or add shielding.
- Energy accumulation drifts after long service: recheck zero drift, temperature compensation and the calibration interval.